H5910 GSM/CDMA Data Acquisition Messenger

1. General

Nowadays, many types of equipment do provide some form of alarm signal to interface to monitoring devices for reporting of various malfunctions or abnormalities; and many operators do want to know their equipment operation status at anytime and anywhere. There are various kinds of signal that the equipment can send out, most common of which are open or closure of one or more switch (relay) contacts. For instance, telecom relay stations (i.e. BTS, Microwave relay station) usually provide signals such as incoming power fail, battery mode, battery level low and switchover failure. An air-conditioner system may provide signals such as power on/off, compressor over-temperature. Also there are many requirements to monitoring warehouse and household door status, temperature and humidity, etc.

H5910 DAM (Data Acquisition Messenger) is a device developed by Hongdian to provide the Short Message Service (SMS) for those applications. It is an enhanced SMS messenger (GPRS or CDMA 1x service optional) integrated with RTU (Remote Terminal Unit) functions.

The equipments to be monitored are connected to H5910 DAM using these alarm signaling contacts. H5910 DAM keeps a constant watch over all the contacts. Whenever any contact input changes of status (either from close to open or from open to close), it is captured by H5910 DAM. It will then process the input according to the settings configured by the user. Then the messages will be sent to one or more mobile phones and/or the supervision centers via SMS.


H5910 DAM is designed with the industrial class hardware platform. It works standalone. Just install and use it. No further development works are required.

H5900 family product includes:

  • H5910 DAM (Data Acquisition Messenger)

H5910 Data Acquisition Messenger is a device with Mini RTU + GSM/CDMA Module, provides 8 RI inputs, 2 RM inputs or 2 RC outputs and 1 RS-232/485 serial interface.

  • H5920 DAM (Data Acquisition Manager)

H5920 Data Acquisition Manager is a full function RTU + GPRS/CDMA 1x Module, provides 8 RI inputs, 8 RM inputs, 4 RC outputs and 2 RS-232/485 serial interface (depends the type of configuration). It can be extended accordingly. With the built-in Web server, it can be accessed via web interface.

H5920 Data Acquisition Manager is an ARM CPU and Linux operation system based platform. It can receive and manage the messages from/to H5910 DAM.

  • Centra2000 Center Software Platform

It is a high performance supervision and control platform from the third party.

Note:
RI=Remote Indication (Digital input)
RM=Remote Measurement (Analog input)
RC=Remote Control (Digital output)

H5900 DAM system can used in many applications, the below diagram is the typical system configuration.

The below is H5910 GSM/CDMA DAM schematic block diagram.

 H5910 GSM/CDMA DAM Block Diagram

2. Features

 
Basic
  • Integrated SMS and RTU functions
  • Support multi-band GSM or CDMA network
  • Send messages to normal mobile handset
  • Send messages to supervision center
  • Support digital/analogue inputs and digital outputs
  • Plug and Play, no development required
  • Compact, flexible, reliable and easy to use
Enhanced
  • Remote configuration
  • Remote SMS contents editing
  • Remote querying
  • SMS receipt and acknowledgement
  • Support RS-232/485 serial interface
  • Support GPRS or CDMA 1x (Optional)
  • Enhanced EMC/EMI design

Remote configuration and editing

As we know, re-assigning of operation personnel, a change of mobile phone number is also common. H5910 DAM allows users to remotely add, change or delete any mobile phone numbers in H5910 DAM memory. Therefore, the authorized personnel can perform the change from anywhere using their mobile phone. Where there are many installed sites, this feature saves time and cost.

H5910 DAM also has a feature to allow users to remotely define the SMS contents including the site name, message description, over-limitation, receipt and so on. The remote indications can be defined in accordance with the events property by the operator. There are four grades can be defined:

  • Fatal: indicates the equipment or system does not work.
  • Serious: indicates the equipment or system performance will be decreased.
  • Warning: indicates the equipment or system is something wrong.
  • Notice: indicates the equipment or system operation status has been changed.

Remote querying

Authorized users can also send the specified SMS to query the status of remote indication/measurement inputs or remote control outputs. This is very useful feature to determine the present status of monitored equipments.

SMS receipt and acknowledgement

If the receipt function enabled, when an alarm is triggered, it will request a receipt from the SMS receiver to confirm if the SMS has been sent, and then log this receipt at the center server (if it is available).

If an alarm happened repeatedly at a specified interval (can be set by user), the SMS will be sent repeatedly to the users. To cancel repeat sending, any mobile phone that received the SMS can acknowledge to H5910 DAM by replying the acknowledge command. Once H5910 DAM received the acknowledgement command is will stop sending further SMS for this trigger.

RS-232/485 serial interface

At many circumstances, there is an equipment (i.e. power meter, RTU, etc.) with RS-232 or 485 data interface. H5920 DAM provides a serial port interface for this connection.

For the specified device, Hongdian can provide the protocol conversion software, and then send the related messages to mobile phone user.
 

3. Specifications

 
GSM/CDMA
  • GSM/GPRS 900/1800 or
  • CDMA/CDMA 1X
Interface
  • Antenna: 50Ω/SMA Female
  • SIM/R-UIM: 3V
  • RI: 8 inputs (photo-isolated)
  • RM: 2 inputs (0~+5VDC, optional)
  • RC: 2 outputs (optional)
  • RI/RM/RC terminal: 3.5 pluggable terminal block
  • Serial port: 1 RS-232 or 485

Power

  • Voltage: +5VDC (-24~-48VDC optional)
  • Consumption: 400mA@+5VDC

Others

  • Measurement: 93x54x22 (not include antenna)
  • Weight: 380g
  • Operation temperature: -10~+55ºC
  • Storage temperature: -40~+85ºC
  • Relative humidity: 95% (no-condensing)

4. Applications

H5900 family products can be used for many industrial applications, such as:

  • Telecom relay stations (BTS, microwave station)
  • Substation
  • Weather station
  • Hydrologic data acquisition
  • Pipe line supervision
  • Standby power generator
  • Electrical distribution panel
  • Warehouse monitoring
  • Vending machine
  • Fire alarm panel
  • ATM
  • Security system
  • Office and household supervision

Application example: Mobile base station monitoring